『Short-term use organ/bronchial tube/catheter / Jane 20-4414』 Instruction manual

■Item name/Item approval number: Short-term use organ/bronchial tube/catheter/Jane No. 20-4414

■Packing unit: 1EA

■Model name: XXXXX

■Manufacturing date: XXXXXX

■Manufacturing number: XXXXXX

■Expiration date: Within 3 years from the date of manufacture

■Manufacturer: Inseong Medical Co., Ltd., 168 Geoepdosi-ro, Jijeong-myeon, Wonju-si, Gangwon-do

■Manufacturing license number: No. 838

■Attached documents are provided in electronic form on the Internet homepage below.

http://www.insungmedical.co.kr/customer/userguide/

■User’s manual creation date: July 3, 2023 (rev. 1)

■ Do not reuse, sterilized disposable medical devices

[Attachment information]

■Purpose of use

1. Short-term use tracheobronchial tube catheter: A tube or catheter inserted through a tracheostomy or oral cavity to secure the airway for short-term use.

2. Internal general-purpose probe: Internal general-purpose probe that transmits and measures signals from probes and detectors.

■ How to use and operating sequence

① Select the specifications of the product to be used on the patient and open the packaging.

② Inject air using a syringe to check for any abnormalities in the cuff.

③ If there is no problem, use the syringe again to remove the air in the cuff.

④ Insert the product through the patient’s mouth until the cuff is located in the trachea.

⑤ Using a syringe, inject air below the maximum level into the cuff and secure the cuff within the patient's trachea.

⑥ After intubation, inject air using a syringe to inflate the cuff and secure it within the trachea.

⑦ If necessary, connect the temperature sensor connector to the monitoring device to measure body temperature.

■Storage method: Avoid direct sunlight and store in a cool place. (Store at room temperature)

■Packaging unit: 1EA

■Manufacturer (importer): Inseong Medical Co., Ltd., 168 Geoepdosi-ro, Jijeong-myeon, Wonju-si, Gangwon-do

■Manufacturing License Number: No. 838

■This is a disposable sterilized medical device, and reuse and re-sterilization are prohibited.

■User’s manual creation date: July 3, 2023 (rev.1)



 Privacy Policy      l     Mail-order-sales Registration No.: 제 2023-강원원주-00727 

 Insung Medical Co., Ltd.    l     LTD CEO : Song In Keum     l     Company Registration Number : 216-81-07039      l     Tel : +82-33-812-3800     l     Fax : +82-33-812-3010     

 168.Gieopdosi-ro, Jijeong-myeon, Won-ju-si, Gangwon-do, Repubulic of korea     l     COPYRIGHTⓒ 2023 INSUNG MEDICAL Co., Ltd. RIGHTS RESERVED.

INSUNG Medical Co., LTD.


Production Division

168, Gieopdosi-ro, Jijeong-myeon, 

Wonju-si, Gangwon-do, Republic of Korea


TEL - +82 33 812 3800

Email - hr@insungmedical.co.kr